Skip to Content

Advanced 500 LPH RO Cum DM Plant

https://www.hydrosoft.in/web/image/product.template/39/image_1920?unique=018480f
500 LPH RO Cum DM Plant – Ultra-Pure Water Purification System

₹ 1,99,990.00 199990.0 INR ₹ 1,99,990.00 Tax Excluded

₹ 1,99,990.00 Tax Excluded

Not Available For Sale

This combination does not exist.

DM Plant

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Product Advantages

Dual Purification Technology – Combines Reverse Osmosis (RO) and Demineralization (DM) for superior water quality.

High-Capacity Output – Produces 500 liters per hour of ultra-pure water.

99.9% TDS and Ion Removal – Eliminates dissolved solids, heavy metals, and mineral ions effectively.

Low Conductivity Water – Delivers water with conductivity as low as <1 Microsiemens/cm.

Advanced Multi-Stage Filtration – Includes pre-filters, carbon filters, RO membranes, and ion-exchange resins.

Sturdy and Durable Construction – Made from corrosion-resistant FRP or stainless steel for long-lasting use.

Energy-Efficient Operation – Low power consumption with optimal performance.

User-Friendly Maintenance – Easy resin regeneration, filter replacement, and system monitoring.

Automatic and Semi-Automatic Models – Available in various configurations to suit user preferences.

Ideal for Industrial Applications – Suitable for pharmaceuticals, laboratories, food processing, and electronics manufacturing.

Highlighted Specifications

FeatureSpecification
Capacity500 LPH
TechnologyReverse Osmosis + Demineralization
TDS RemovalUp to 99.9%
Resin TypeCation & Anion Exchange Resins
Output Conductivity<1 Microsiemens/cm
MaterialFRP / Stainless Steel
AutomationFully Automatic / Semi-Automatic
Power Consumption2-4 kW
Operating Voltage220V AC
Warranty1 Year

Customer Support

📞 For installation, service, or troubleshooting, call our Customer Care Number: 8800199166.

Our expert team is available 24/7 to assist you with queries and maintenance support.

Product Do’s & Don’ts

Do’s:

✔ Regularly check water output quality, including TDS and conductivity levels.

✔ Follow scheduled resin regeneration and membrane cleaning for long-term efficiency.

✔ Ensure proper pre-filtration to protect the RO membranes and resin bed.

✔ Keep the system in a dry, well-ventilated location to avoid damage.

✔ Use only manufacturer-approved chemicals for cleaning and regeneration.

Don’ts:

Do not skip regular maintenance, as it affects water quality and system lifespan.

Avoid overloading the system beyond its designed capacity.

Never use unfiltered raw water as input; always pre-treat it if necessary.

Do not ignore pressure drops, leaks, or alarms as they may indicate critical issues.

Troubleshooting Guide

💧 Issue: Low Water Flow

🔹 Solution: Check for clogged filters, exhausted resin, or membrane fouling.

💧 Issue: High Conductivity in Output Water

🔹 Solution: Indicates exhausted resin or damaged membranes; replace as necessary.

💧 Issue: Leakage from the System

🔹 Solution: Inspect pipe fittings and replace damaged seals.

💧 Issue: Pump Not Working

🔹 Solution: Ensure proper power supply and check for pressure-related issues.

💧 Issue: Unusual Noise or Vibrations

🔹 Solution: Could indicate a faulty pump or airlock in the system; check for blockages.

📞 For unresolved issues, call our support team at 8800199166.

Service & Maintenance Schedule

📅 Pre-Filters & Carbon Filters: Replace every 3-6 months.

📅 RO Membranes: Clean every 6 months and replace every 12-18 months.

📅 Cation & Anion Resins: Regenerate every 3-6 months; replace yearly.

📅 UV Sterilizer (if equipped): Replace the UV lamp annually.

📅 Pump & Motor Inspection: Perform check-ups every 6 months for optimal efficiency.

📞 Opt for our Annual Maintenance Contract (AMC) for worry-free servicing and periodic maintenance.

Installation Guide

1️⃣ Choose a Suitable Location – Install in a well-ventilated area with a stable base.

2️⃣ Connect Pre-Filters and Pipelines – Ensure proper input and output piping for seamless water flow.

3️⃣ Electrical Setup – Use a stabilizer to prevent voltage fluctuations.

4️⃣ Flush the System Before Use – Run water through the filters and membranes to remove residual particles.

5️⃣ Conduct a Quality Check – Test TDS and conductivity to ensure optimal performance.

📞 For professional installation, contact our technical team at 8800199166.

FAQs – 500 LPH RO Cum DM Plant

Q1: What is the primary purpose of the 500 LPH RO Cum DM Plant?

✔ It is designed to produce ultra-pure water by removing dissolved salts, ions, and contaminants, making it ideal for industrial and laboratory use.

Q2: How frequently should the resin be regenerated?

✔ Regeneration should be done every 3-6 months, depending on water quality and usage.

Q3: What is the system’s warranty period?

✔ The plant comes with a 1-year warranty, covering manufacturing defects.

Q4: Can I install the system myself?

Professional installation is recommended for optimal performance.

Q5: Does the system remove bacteria and viruses?

✔ If equipped with a UV sterilizer, it effectively eliminates microorganisms, ensuring safe water.

Q6: What power supply is needed for this plant?

✔ The system operates on 220V AC with 2-4 kW power consumption.

Q7: How can I ensure the longevity of the plant?

Regular maintenance, timely filter replacements, and scheduled servicing will enhance system performance and durability.

📞 For more queries, contact 8800199166.