Advanced 500 LPH RO Cum DM Plant
500 LPH RO Cum DM Plant – Ultra-Pure Water Purification System
Product Advantages
✅ Dual Purification Technology – Combines Reverse Osmosis (RO) and Demineralization (DM) for superior water quality.
✅ High-Capacity Output – Produces 500 liters per hour of ultra-pure water.
✅ 99.9% TDS and Ion Removal – Eliminates dissolved solids, heavy metals, and mineral ions effectively.
✅ Low Conductivity Water – Delivers water with conductivity as low as <1 Microsiemens/cm.
✅ Advanced Multi-Stage Filtration – Includes pre-filters, carbon filters, RO membranes, and ion-exchange resins.
✅ Sturdy and Durable Construction – Made from corrosion-resistant FRP or stainless steel for long-lasting use.
✅ Energy-Efficient Operation – Low power consumption with optimal performance.
✅ User-Friendly Maintenance – Easy resin regeneration, filter replacement, and system monitoring.
✅ Automatic and Semi-Automatic Models – Available in various configurations to suit user preferences.
✅ Ideal for Industrial Applications – Suitable for pharmaceuticals, laboratories, food processing, and electronics manufacturing.
Highlighted Specifications
Feature | Specification |
---|---|
Capacity | 500 LPH |
Technology | Reverse Osmosis + Demineralization |
TDS Removal | Up to 99.9% |
Resin Type | Cation & Anion Exchange Resins |
Output Conductivity | <1 Microsiemens/cm |
Material | FRP / Stainless Steel |
Automation | Fully Automatic / Semi-Automatic |
Power Consumption | 2-4 kW |
Operating Voltage | 220V AC |
Warranty | 1 Year |
Customer Support
📞 For installation, service, or troubleshooting, call our Customer Care Number: 8800199166.
Our expert team is available 24/7 to assist you with queries and maintenance support.
Product Do’s & Don’ts
✅ Do’s:
✔ Regularly check water output quality, including TDS and conductivity levels.
✔ Follow scheduled resin regeneration and membrane cleaning for long-term efficiency.
✔ Ensure proper pre-filtration to protect the RO membranes and resin bed.
✔ Keep the system in a dry, well-ventilated location to avoid damage.
✔ Use only manufacturer-approved chemicals for cleaning and regeneration.
❌ Don’ts:
✖ Do not skip regular maintenance, as it affects water quality and system lifespan.
✖ Avoid overloading the system beyond its designed capacity.
✖ Never use unfiltered raw water as input; always pre-treat it if necessary.
✖ Do not ignore pressure drops, leaks, or alarms as they may indicate critical issues.
Troubleshooting Guide
💧 Issue: Low Water Flow
🔹 Solution: Check for clogged filters, exhausted resin, or membrane fouling.
💧 Issue: High Conductivity in Output Water
🔹 Solution: Indicates exhausted resin or damaged membranes; replace as necessary.
💧 Issue: Leakage from the System
🔹 Solution: Inspect pipe fittings and replace damaged seals.
💧 Issue: Pump Not Working
🔹 Solution: Ensure proper power supply and check for pressure-related issues.
💧 Issue: Unusual Noise or Vibrations
🔹 Solution: Could indicate a faulty pump or airlock in the system; check for blockages.
📞 For unresolved issues, call our support team at 8800199166.
Service & Maintenance Schedule
📅 Pre-Filters & Carbon Filters: Replace every 3-6 months.
📅 RO Membranes: Clean every 6 months and replace every 12-18 months.
📅 Cation & Anion Resins: Regenerate every 3-6 months; replace yearly.
📅 UV Sterilizer (if equipped): Replace the UV lamp annually.
📅 Pump & Motor Inspection: Perform check-ups every 6 months for optimal efficiency.
📞 Opt for our Annual Maintenance Contract (AMC) for worry-free servicing and periodic maintenance.
Installation Guide
1️⃣ Choose a Suitable Location – Install in a well-ventilated area with a stable base.
2️⃣ Connect Pre-Filters and Pipelines – Ensure proper input and output piping for seamless water flow.
3️⃣ Electrical Setup – Use a stabilizer to prevent voltage fluctuations.
4️⃣ Flush the System Before Use – Run water through the filters and membranes to remove residual particles.
5️⃣ Conduct a Quality Check – Test TDS and conductivity to ensure optimal performance.
📞 For professional installation, contact our technical team at 8800199166.
FAQs – 500 LPH RO Cum DM Plant
❓ Q1: What is the primary purpose of the 500 LPH RO Cum DM Plant?
✔ It is designed to produce ultra-pure water by removing dissolved salts, ions, and contaminants, making it ideal for industrial and laboratory use.
❓ Q2: How frequently should the resin be regenerated?
✔ Regeneration should be done every 3-6 months, depending on water quality and usage.
❓ Q3: What is the system’s warranty period?
✔ The plant comes with a 1-year warranty, covering manufacturing defects.
❓ Q4: Can I install the system myself?
✔ Professional installation is recommended for optimal performance.
❓ Q5: Does the system remove bacteria and viruses?
✔ If equipped with a UV sterilizer, it effectively eliminates microorganisms, ensuring safe water.
❓ Q6: What power supply is needed for this plant?
✔ The system operates on 220V AC with 2-4 kW power consumption.
❓ Q7: How can I ensure the longevity of the plant?
✔ Regular maintenance, timely filter replacements, and scheduled servicing will enhance system performance and durability.
📞 For more queries, contact 8800199166.