Product Advantages

  • Dual Purification Technology: Combines Reverse Osmosis (RO) and Demineralization (DM) for ultra-pure water.
  • 250 LPH Capacity: Suitable for industrial, pharmaceutical, and laboratory applications.
  • High Purity Water Output: Removes dissolved salts, minerals, and contaminants, ensuring ultra-low TDS.
  • Fully Automatic & Semi-Automatic Options: Available in manual, semi-automatic, and fully automatic models.
  • Compact & Space-Saving Design: Ideal for areas with limited installation space.
  • Low Maintenance & Easy Operation: Simple resin replacement and filter changes ensure seamless operation.
  • Energy-Efficient System: Optimized for low power consumption and maximum output.
  • Corrosion-Resistant Build: Constructed using stainless steel/FRP materials for long-lasting durability.
  • Advanced Filtration Stages: Includes pre-filtration, RO membrane, cation & anion resin chambers, and UV sterilization.
  • Reliable and Consistent Performance: Ensures stable water quality for high-precision applications.

Highlight Specifications

FeatureSpecification
Capacity250 LPH
TechnologyRO + Ion-Exchange Deionization
Resin TypeCation & Anion Exchange Resins
RO MembraneHigh-Efficiency TFC Membrane
Power Consumption1.5-2.5 kW
Operating Voltage220V AC
MaterialStainless Steel/FRP
AutomationFully Automatic/Semi-Automatic
TDS ReductionUp to 99.9%
Conductivity Output<1 Microsiemens/cm
Warranty1 Year

Product Customer Care Number

For installation, maintenance, or troubleshooting support, contact our Customer Care Number: 8800199166. Our expert team is available 24/7 for assistance.

Product Related Do’s & Don’ts

Do’s:

  • Regularly monitor the TDS and conductivity of output water.
  • Replace RO membranes and resin as per the recommended maintenance schedule.
  • Keep the system in a dry, ventilated space for optimal efficiency.
  • Use a voltage stabilizer to prevent electrical damage.
  • Follow proper regeneration and resin replacement procedures.

Don’ts:

  • Do not run the system with exhausted resin or clogged filters.
  • Avoid using untreated high-TDS water without pre-filtration.
  • Do not ignore system alarms or warning indicators.
  • Never use unauthorized chemicals for cleaning or regeneration.

Product Repair Troubleshoots

Common Issues & Solutions:

  • Low Water Flow: Check for clogged filters, membrane blockage, or resin exhaustion.
  • High TDS in Output Water: Resin may need regeneration or replacement; RO membrane could be worn out.
  • Leakages in System: Inspect all pipe fittings and O-rings for wear and tear.
  • Electrical Malfunction: Ensure a stable power supply and check circuit connections.
  • Unusual Noises: Could indicate a failing pump or improper system pressure.

Product Service Guide and Future Service Schedule Information

Maintenance Schedule:

  • Pre-Filters & Carbon Filters: Replace every 3-6 months.
  • RO Membrane: Replace every 12-18 months depending on water quality.
  • Cation & Anion Resins: Regenerate every 3-6 months or replace annually.
  • Pump & Motor Check-up: Every 6 months.
  • Annual System Inspection: Essential for optimal efficiency and longevity.

Service Assistance: Opt for our Annual Maintenance Contract (AMC) for hassle-free servicing and uninterrupted plant performance.

Product Installation Guide

  1. Select an Installation Area: Ensure a well-ventilated space near the water inlet.
  2. Connect the Components: Assemble the pre-filters, RO membrane, resin chambers, and UV system properly.
  3. Electrical Setup: Use a voltage stabilizer to avoid electrical fluctuations.
  4. Initial Rinse: Flush the system with clean water before use.
  5. Check for Leaks & Pressure Settings: Inspect connections before full operation.

For professional installation, contact our support team.

FAQs

Q1: What is the ideal input water TDS for this RO Cum DM Plant? A1: The system is designed for input water with TDS below 1500 ppm. Pre-treatment may be required for higher levels.

Q2: How often should the RO membrane and resin be replaced? A2: RO membranes last 12-18 months, while resin should be regenerated every 3-6 months and replaced annually.

Q3: What is the warranty period? A3: The plant comes with a 1-year warranty covering manufacturing defects.

Q4: Can I install the plant myself? A4: While self-installation is possible, we recommend professional installation to ensure proper setup and warranty validity.

Q5: What power supply is needed for the plant? A5: The plant requires 220V AC with a power consumption of 1.5-2.5 kW.

Q6: Does the system remove bacteria and viruses? A6: Yes, the RO membrane removes most contaminants, while the UV sterilizer eliminates microorganisms.

Q7: How can I ensure the longevity of the plant? A7: Regular maintenance, timely filter changes, and proper resin regeneration will ensure long-term efficiency