Skip to Content

High-Efficiency 500 LPH DM Plant

https://www.hydrosoft.in/web/image/product.template/38/image_1920?unique=822cff3
500 LPH Industrial Demineralization (DM) Water Plant – High-Purity Water Solution

₹ 1,25,000.00 125000.0 INR ₹ 1,25,000.00 Tax Excluded

₹ 1,25,000.00 Tax Excluded

Not Available For Sale

This combination does not exist.

DM Plant

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Product Advantages

  • High-Capacity Purification: Produces 500 liters per hour of demineralized water for various applications.
  • Superior Ion-Exchange Technology: Uses high-quality cation and anion resins for effective removal of dissolved salts.
  • Ultra-Low Conductivity Output: Delivers water with a conductivity of <1 Microsiemens/cm, ideal for industrial and laboratory use.
  • Compact and Space-Efficient Design: Designed for easy installation in limited spaces.
  • Fully & Semi-Automatic Options: Available in manual, semi-automatic, and fully automatic configurations.
  • Corrosion-Resistant Build: Constructed with high-quality stainless steel or FRP for durability.
  • Low Power Consumption: Energy-efficient system optimized for minimal electricity usage.
  • User-Friendly Operation: Easy maintenance with simple resin regeneration and filter replacement procedures.
  • Multi-Stage Filtration: Ensures superior water quality with pre-filtration, resin treatment, and UV sterilization.
  • Reliable and Consistent Performance: Ideal for industries such as pharmaceuticals, power plants, and electronics manufacturing.

Highlight Specifications:

FeatureSpecification
Capacity500 LPH
TechnologyIon-Exchange Demineralization
Resin TypeCation & Anion Exchange Resins
Power Consumption2-3 kW
Operating Voltage220V AC
MaterialStainless Steel/FRP
AutomationFully Automatic/Semi-Automatic
Conductivity Output<1 Microsiemens/cm
TDS RemovalUp to 99.9%
Warranty1 Year

Product Customer Care Number For installation, maintenance, or troubleshooting support, contact our Customer Care Number: 8800199166. Our technical team is available 24/7 for assistance.

Product Related Do’s & Don’ts

Do’s:

  • Regularly monitor output water quality, including TDS and conductivity levels.
  • Follow scheduled resin regeneration and replacement to maintain efficiency.
  • Keep the system in a dry, ventilated area to prevent damage.
  • Use only approved regeneration chemicals to ensure the longevity of resins.
  • Follow proper electrical safety measures to avoid system damage.

Don’ts:

  • Do not operate the system without sufficient pre-filtration for high-TDS water.
  • Avoid skipping scheduled maintenance, as it can reduce water quality.
  • Do not use unapproved chemicals for cleaning or regeneration.
  • Never ignore pressure fluctuations or alarms, as they indicate potential system issues.

Product Repair Troubleshoots

Common Issues & Solutions:

  • Low Water Output: Check for clogged pre-filters, exhausted resin, or low inlet pressure.
  • High Conductivity in Output Water: Indicates exhausted resin; requires regeneration or replacement.
  • Leakages: Inspect pipe connections and O-rings for wear and tear.
  • Pump Malfunction: Check for proper voltage supply and pressure settings.
  • Unusual Noises: Could indicate faulty pumps or pressure fluctuations.

Product Service Guide and Future Service Schedule Information

Maintenance Schedule:

  • Pre-Filters: Replace every 3-6 months.
  • Cation & Anion Resins: Regenerate every 3-6 months; replace annually.
  • UV Sterilizer (if applicable): Replace bulb every 12 months.
  • Pump & Motor Check-up: Inspect every 6 months for optimal performance.
  • Annual System Inspection: Ensures long-term efficiency and reliability.

Service Assistance: Opt for our Annual Maintenance Contract (AMC) for scheduled servicing and hassle-free operation.

Product Installation Guide

  1. Choose an Installation Location: Ensure a dry, well-ventilated area close to a water inlet.
  2. Assemble Components: Connect pre-filters, resin chambers, and outlet pipes as per the manual.
  3. Electrical Setup: Use a stabilizer to prevent voltage fluctuations.
  4. System Rinse: Flush the system before first use to remove residual particles.
  5. Final Inspection: Check for leaks and test conductivity before full operation.

For professional installation, contact our support team.

FAQs

Q1: What is the ideal input water TDS for this DM Plant?

A1: The system is designed for input water with TDS below 500 ppm. Pre-treatment may be needed for higher levels.

Q2: How often should the resin be regenerated?

A2: Resin should be regenerated every 3-6 months and replaced annually for best performance.

Q3: What is the warranty period?

A3: The plant comes with a 1-year warranty covering manufacturing defects.

Q4: Can I install the plant myself?

A4: Professional installation is recommended to ensure proper setup and avoid operational issues.

Q5: What power supply is needed for the plant?

A5: The plant operates on 220V AC with power consumption of 2-3 kW.

Q6: Does the system remove bacteria and viruses?

A6: If equipped with a UV sterilizer, it can eliminate microorganisms effectively.

Q7: How can I ensure the longevity of the plant?

A7: Regular maintenance, timely resin regeneration, and proper filter changes will ensure optimal performance.